Corrosion of surface facilities of an industrial concern in the niger delta area of Nigeria splased by produced water
- Open access
- Peer reviewed
- CC BY 4.0
ISSN 2992-4383
Authors
- C. N. Anyakwo Corresponding author
Abstract
A study of uniform corrosion of carbon steel pipeline by produced water that splashed continuously on it is presented. The predominantlyuniform attack was essentially the conventional corrosion mechanism that was accelerated by chloride-assisted CO2 corrosion additive.The high Cl and3 HCO contents of the produced water were additional corrosion drivers. The paint was rapidly destroyed by the Clions of the produced water, thus exposing the metal predominantly to uniform corrosion. Attempts to wire-brush the corroded steel,preparatory to repainting them led to leakages. The corrosion incidence was remedied by the abatement of discharge of the produced waterfrom the line and replacement of the lines that developed sporadic leaks at different intervals and different points. Insulation of the facilitiesfrom contact with the produced water could also suffice to stop the attack. The importance of ensuring that produced water does not splashor come into contact with the external surface of any facility during drainage, is underscored.